How to maintain ultrasonic welding machine
In the process of production and use, the maintenance of ultrasonic mold and ultrasonic welding machine is very important. A well maintained ultrasonic welding machine can be used for 10 years without much difference from the new one in appearance and performance. Some customers don't pay attention to maintenance, and there will be a lot of small problems in less than one or two years. This is the biggest difference between maintenance and not maintenance, so the ultrasonic machine also needs maintenance, The following are the maintenance methods of ultrasonic welding machine:
1: If not used for more than one week, please cover it with dust cover (plastic bag).
2: Except that the lifting screw has received lubricating oil before leaving the factory, other parts do not need any oil.
3: Regularly check the internal vibrator output line for wear.
4: If there is dust on the outside, please wipe it with a clean cloth. Dry compressed air should be used to clean the dust in the machine every six months. It is strictly forbidden to use various fluxes when cleaning the side plate and surface of the welding machine. Neutral detergent should be used to wipe it gently.
5: When the water level of the filter cup reaches 1 / 3, please drain the water.
6. When the welder is used for one month, the sliding part shall be cleaned and re coated with high-quality lubricating grease.
7: Pay attention to the safety of machine position at any time.
As long as the above 7 points are achieved, youwo ultrasonic can say that your ultrasonic machine has no fault in 3-5 years. We need to implement these small details, and the execution is very important